Thermal conductivity reading system with a measurement area of at least 600 × 600 mm for boards, loose-fill and compressible specimens. The specimen sits between two temperature-controlled plates; the steady heat flow is measured and thermal conductivity is calculated from the plate temperature diff…

RTPLINE-AL-λ 600
RTPLINE
9024800000
✔ Reply within 1 business day ✔ 12-month parts warranty ✔ Installation & training support
Quick Answer Updated November 2026

Misuratore di flusso di calore - Configurazione della misurazione della conducibilità termica (AL-λ 600) is a piece of pipe testing equipment from RTPLINE.

About This Machine

Product Overview

Thermal conductivity reading system with a measurement area of at least 600 × 600 mm for boards, loose-fill and compressible specimens. The specimen sits between two temperature-controlled plates; the steady heat flow is measured and thermal conductivity is calculated from the plate temperature difference, specimen thickness and heat flow sensor data. Covers 0.002–2 W/(m·K) at −20 °C to 90 °C.

Core Features

  • Measurement area of at least 600 × 600 mm
  • Thermal conductivity range: 0.002–2 W/(m·K)
  • Measurement temperature: −20 °C to 90 °C
  • Repeatability ±0.25 %, temperature stability ±0.05 °C
  • Motorized upper plate with parallel, repeatable specimen contact
  • Controlled compression at 5 kPa and 10 kPa contact pressure for TS EN 12667
  • Target thickness regulation: upper plate moves automatically to the set specimen thickness
  • Low-resistance specimens below 0.3 m²K/W with external thermocouples and compensation mats
  • PC + touchscreen regulation, automatic Excel / Word / PDF reports, remote service

Standards

  • TS EN 12667 — Thermal capability of building substances and products — determination of thermal resistance by means of guarded hot plate and heat flow meter methods — products of high and medium thermal resistance
  • TS EN 12664 — Thermal performance of building materials and products — determination of thermal resistance by means of guarded hot plate and heat flow meter methods — products of medium and low thermal resistance
  • TS 415 EN 12939 — Thermal capability of building substances and products — thick products of high and medium thermal resistance
  • ASTM C518 — Steady-state thermal transmission properties by means of the heat flow meter apparatus
  • ISO 8301 — Thermal insulation — determination of steady-state thermal resistance and related properties — heat flow meter instrument

Specifications

  • Thermal Conductivity Range0.002–2 W/(m·K)
  • Minimum Reading Area600 × 600 mm
  • Reading Temperature−20 °C … 90 °C
  • Plate Setpoint Range−10 °C … 60 °C
  • Accuracy (vs. reference substance)±1 % – ±2 %
  • Accuracy with Calibration SpecificationBetter than ±1 %
  • Repeatability±0.25 %
  • Reproducibility±0.5 %
  • Temperature Stability±0.05 °C or better
  • Setpoint Accuracy±0.03 °C or better

Heating Time (10 °C rise): < 10 min (typical)

  • Heating CapacityMin. 2,000 W
  • Cooling CapacityMin. 840 W (at 20 °C)
  • Contact Pressure5 kPa; 10 kPa (TS EN 12667)
  • Calibration ReferencesEPS specification 600 × 600 × 25 mm; ERM-FC440C 600 × 600 × 28.7 mm
  • SoftwareWindows 10/11 (64-bit), up to four devices on one PC, QS/ERP integration
Technical Data

Specifications

ParameterSpecification
ModelRTPLINE-AL-λ 600
BrandRTPLINE
Code9024800000

Specifications are configurable to your pipe sizes and test standard. Ask us for the full datasheet and a configuration proposal.

Source: RTPLINE product engineering data · Updated November 2026

FAQ
How many test stations do I need?
Answer: It depends on how many samples you run per day. For occasional testing with a few samples, 3–6 stations are sufficient. For daily batch release or a busy test house, choose 5–30 stations so long-duration tests run in parallel instead of queueing. Send us your daily sample count and we will size the station number for you.
How do I get pricing and a recommended configuration?
Answer: Tell us the pipe diameter range, the test standard (for example ISO 1167 or ASTM D1598/D1599), the number of stations you need and the water-bath size you expect. We will return a configuration proposal with a firm quotation, lead time and shipping terms — normally within one business day.
What are your strengths?
Answer: RTPLINE designs, builds and tests plastic pipe testing and extrusion equipment in-house. Critical components are selected for continuous industrial duty, and every unit is pressure-tested and run before shipment, so performance is repeatable from the first day on your floor.
How will the machine be assembled and debugged when it arrives at the factory, and will the customer's employees be trained?
Answer: The equipment is assembled and debugged at our works before delivery, then packed for shipment. Our engineers provide remote video guidance for installation and commissioning, and on-site installation and operator training can be arranged. Training covers daily operation, changeover, routine maintenance and safety.
What do you do if there is a problem or failure with equipment that requires guidance or replacement parts?
Answer: Send us the symptom and a short video; our service team replies with a diagnosis and step-by-step guidance. If remote support cannot solve it, an engineer can be dispatched to site. Parts replaced during the warranty period are supplied free of charge; wear parts are charged at cost only.
How long is the warranty period of the product?
Answer: Every machine carries a 12-month parts warranty together with lifetime technical support. Consumables and wear parts are excluded, and are quoted at cost.
Can I visit your factory in China?
Answer: Yes. Factory visits are welcome — we can arrange airport pickup and a full demonstration of the machine running with your pipe samples. Video tours are also available if travel is not convenient.
Can you customize according to requirements?
Answer: Yes. Working range, number of stations, fixture sizes, voltage, control interface and guarding can be customized to your pipe sizes, test standard and plant layout. Send your specification and we will propose a configuration.