Studi Model mengenai Sifat Mekanis Pipa Mortar Plastik yang Diperkuat Serat Kaca pada Gorong-gorong di Bawah Tanggul yang Ditinggikan

Penulis: Huawang Shi Sumber: International Journal of Performability Engineering (2018) DOI: 10.23940/ijpe.18.06.p27.13521359 Tabung mortar polimer yang diperk

Studi Model mengenai Sifat Mekanis Pipa Mortar Plastik yang Diperkuat Serat Kaca pada Gorong-gorong di Bawah Tanggul yang Ditinggikan
Penulis: Huawang Shi
Sumber: International Journal of Performability Engineering (2018)
DOI: 10.23940/ijpe.18.06.p27.13521359

Tabung mortar polimer yang diperkuat serat kaca merupakan jenis material komposit baru. Untuk memperoleh parameter desain dan konstruksi serta mengidentifikasi penyebab retak pada gorong-gorong tabung mortar polimer yang diperkuat serat kaca (FRPM) dengan pengisian tinggi, dilakukan studi model terhadap sifat mekanik gorong-gorong FRPM. Hasil penelitian menunjukkan bahwa pola deformasi tegangan atau regangan melingkar konsisten; seiring dengan peningkatan ketinggian pengisian, pertumbuhan tegangan pada FRPM dan tekanan tanah vertikal bersifat nonlinier. Simulasi pada ketinggian pengisian maksimum 12 m, di bawah beban aksial, nilai tegangan dan regangan melingkar gorong-gorong tersebut adalah 6770 kPa dan 2109 (ε)/(×10⁻⁶); tekanan tanah maksimum terjadi di bagian atas gorong-gorong, dengan nilai 322 kPa; di bawah beban eksentrik, nilai maksimum tegangan dan regangan melingkar masing-masing sebesar 6.092 kPa dan 1.898 (ε)/(×10⁻⁶); sedangkan nilai maksimum tekanan tanah sebesar 183 kPa.
⚡ Minta Penawaran

Contact us for free consultation, quotation and technical support.

Tanyakan Sekarang
WhatsApp QQ Email
Tel / WhatsApp: +86 186 0104 2089
Email: testermachine@aliyun.com
CE Certified · ISO 9001

Summary

Glass-fiber-reinforced plastic (GRP) mortar pipe culverts under elevated embankments are evaluated with ring-stiffness, deflection and sustained-load tests that model soil-pipe interaction and long-term mechanical response.

Frequently Asked Questions

Why test GRP mortar pipe culverts under high embankment load?

Deep embankments impose sustained soil and traffic loads; measuring ring deflection, stiffness and strain verifies that the buried pipe retains structural capacity over its service life.

Which parameters are recorded in the model test?

Vertical and horizontal deflection, pipe strain, bedding reaction, load-step response and residual deformation after unloading.

Last updated: September 23, 2026 · RTPLINE technical team · All applications

Products

Peralatan Terkait

Contact Us

Send Us a Message

Our technical team will reply within 24 hours.

Prefer instant chat? WhatsApp +86 186 0104 2089 · QQ 871507446 · testermachine@aliyun.com
Certified quality
CE, ISO 9001:2015 & ISO 14001
Global delivery
Equipment exported to 140+ countries
Engineered to your standard
ISO / ASTM / API 15S, custom pressure range
Privacy-first enquiry
GDPR-ready, no data resale, reply within 24 h